Redruth Office Building


Location: Redruth, Cornwall
Work Done: Mechanical & Electrical Works To Office Building

The project involved M&E works to a new reception, waiting area, disabled toilet and five (5) examination rooms.

 

Electrical

New lighting has been installed to the new Examination Rooms, Corridors and Reception, they are controlled via independent marshalling boxes (klik) located in each room.

New Emergency Lighting has been installed throughout the new office areas to bring it up to the Latest regulations.

All Examinations rooms, Reception and Corridors have been fitted with Paxton fob access control

New socket outlets and Switched/un-switched fused spur units have been installed throughout the new office areas to accommodate for Power, Access Control and Air Conditioning.

A standalone door intercom system has been installed to the public entrance door, this allows the receptionist to open the electronic door for the clients.

The fire alarm system has been altered to accommodate the new building layout.

Four additional Samsung CCTV cameras have been installed to the corridor and waiting area.

All Electrical wiring throughout the new office Areas has been wired in FP200 as per specification.

 

Mechanical

A new disabled Toilet and sink has been installed within the new Area, JMC had to install a Saniflo to pump the waste from the disabled toilet to the nearest sewage pipe 20 metres away. A cold water supply had to be installed to the disabled toilet from the existing part of the building 20 metres away.

 

Air Conditioning

A Mitsubishi VRF air conditioning System has been installed throughout the new office areas.

The air conditioning system provides heating and cooling at the same time to different rooms, each room has had a controller installed so the temperature can be regulated.

9inch Galvanised tray has been installed above the suspended ceiling throughout the new area, this is for the containment of the copper pipes, PVC flexible drain pipes and Electrical interconnection wiring.

Each Examination room, and reception has a wall mounted unit, the waiting area has a 600x600mm 4way cassette.